上海康桥先进制造技术创业园物业 (上海康桥科技创业园区)

摘要:本远程预付费能源管理系统采用智能远程预付费电表(DTSY1352-NK三相电子式预付费表),采集各用户实时用电量、剩余 ,安科瑞 崔远航,电量,通过智能远程预付费电表进行远程分合闸控制,实现先售电后用电。该系统结构为B/S结构,数据采集采用总线通讯方式传至后台,通过安科瑞(AcrelCloud-3200)远程预付费能源管,安科瑞 崔远航,系统实现各企业用户用电的收费、监控和管理。

Abstract: This remote prepaid energy management system uses a smart remote prepaid meter (DTSY1352-NK three-phase electronic prepaid meter), collects real-time power consumption and remaining power of each user, and remotely opens and closes through the smart remote prepaid meter Control to realize the use of electricity after the sale of electricity. The system structure is a B/S structure, and data collection is transmitted to the background by bus communication, and the charging, monitoring and management of electricity consumption by enterprise users are realized through the AcrelCloud-3200 remote prepaid energy management system.

关键词:DTSY1352-NK三相电子 ,安科瑞 崔远航,式预付费表,B/S,AcrelCloud-3200,总线通讯

Keywords : DTSY1352-NK three-phase electronic prepayment meter, B/S, AcrelCloud-3200, bus communication

1﹑概述Overview

上海康桥先进制造技术创业园目前是上海先进制造技术创业孵化基地。是有专业化特色的高新技术企业培育、高新技术成果转化、高新技术人才培养的基地。

本项已投入运营,现因原有配电结构 ,安科瑞 崔远航,复杂,没有清晰的电力配电结构,有些馈线回路未加装智能电力仪表,导致抄表难、收费难。本次方案改造原有计量表,原表加装预付费智能电表,电表通过采集器把,安科瑞 崔远航,数据上传至预付费云平台,从而完成对所有电表的采集及收费管理。

Shanghai Kangqiao Advanced Manufacturing Technology Pioneer Park is currently an incubation base for Shanghai's advanced manufacturing technology professional entrepreneurship. It is a base for the cultivation of high-tech enterprises with specialized characteristics, the transformation of high-tech achievements, and the training of high-tech talents.

This project has been put into operation.Now because the original power distribution structure is complicated, there is no clear power distribution structure, and some feeder circuits are not equipped with smart power meters, which makes it difficult to read meters and charge fees. In this plan, the original meter will be transformed. The original meter is equipped with a prepaid smart meter. The meter uploads the data to the prepaid cloud platform through the collector, thereby completing the collection and charging management of all meters.

2﹑系统方案 System solutions

根据客户需求及项目 ,安科瑞 崔远航,实际情况,本项目设计的预付费能源管理系统,由安科瑞品牌DTSY1352 三相预付费电能表,多功能智能电表AMC96-E4/C,通讯管理机ANet-2E8S1,数据服务器及预付费平台系统软,安科瑞 崔远航,件等组成。

AcrelCloud-3200远程预付费电能管理系统采用分层分布 ,安科瑞 崔远航,对结构进行设计,即现场设备层、网络通讯层和站控管理层。

According to customer needs and the actual situation of the project, the prepaid energy management system designed by this project is composed of Acrel DTSY1352 three-phase prepaid electric energy meter, multifunctional smart meter AMC96-E4/C, communication management machine ANet-2E8S1, data server and prepaid platform system software.

AcrelCloud-3200 remote prepaid power management system is designed with a hierarchical distributed structure, that is, the field equipment layer, the network communication layer and the station control management layer

预付费能源管理系统开发 ,安科瑞 崔远航,本次地运行和操作流程如下:

The basic operation and operation process of the prepaid energy management system is as follows:

系统安装 System installation

通讯管理机、表、户等系统 ,安科瑞 崔远航, 同配置 System configuration of communication management machine, meter, household, etc.

系统初始化 system initialization

开户配表 Account opening table

金额转入 Amount transferred in

老表有金额 the old watch has an amount

日常购电、退电、充电 Daily power purchase, return, and reconciliation

远程拉闸、合闸,抄表,设 ,安科瑞 崔远航, 置下发 Remote switch on, switch on, meter reading, setting and issuing

销户处理 Account cancellation processing

报表中心 Report Center

打印票据 Print receipt

退出系统 Exit system

3﹑系统主要功能及界面 Main functions and interface of the system

AcrelCloud-3200预付费云平 ,安科瑞 崔远航,台是安科瑞公司新研制的与DTSY-1352三相电子书预付费电能表配套的售电管理系统。它是以预付费管理软件和集中抄表软件为主,包括计算机,通讯管理机,打印机等,安科瑞 崔远航,设置在内的集成系统。

主要完成电能表参数设置,商户售电管理及能耗管理工作,操作简便,实行企业集团、物业公司远程实时操作实时 ,安科瑞 崔远航,监控,具有良好的人机界面,能够有效地统计和管理数据,并对数据的安全性做了有效的保密措施。

Acrel Cloud-3200 prepaid cloud platform is an electricity sales management system newly developed by Acrel to match the DTSY-1352 three-phase e-book prepaid electric energy meter. It is an integrated system based on prepaid management software and centralized meter reading software, including computers, communication management machines, printers and other settings.

It mainly completes the parameter setting of electric energy meters, the management of electricity sales by merchants and the management of energy consumption. It is easy to operate. It implements remote real-time operation and real-time monitoring of enterprise groups and property companies. It has a good man-machine interface and can effectively count and manage data. Effective security measures have been taken for the security.

3.1集中抄表服务系统 Centralized meter reading service system

系统默认半小时对所有表进行一次远程集中抄表,时间间隔支持个性化配置(至少可支持1分钟/次的采集频率)。

This system defaults to perform a remote centralized meter reading for all meters in half an hour, and the time interval supports personalized configuration (at least 1 time/minute collection frequency can be supported).

上海康桥先进制造技术创业园,上海康桥先进制造招商

B/S云平台售电系统 B/S cloud platform electricity sales system

本系统包括五大模块,分别是登陆模块、系统配置模块、用户(商铺)管理模块、售电管理模块、报表中心模块,主要功能如下:

1)登陆管理:管理操作员账户及权限分配,查看系统日志等功能;

2)系统配置:对建筑、通讯管理机、仪表及默认参数进行配置;

3)用户管理:对商铺用户执行开户、销户、远程分合闸、批量操作及记录查询等操作;

4)售电管理:对已开户的表进行 ,安科瑞 崔远航,进行远程售电、退电、冲正及记录查询等操作;

5)报表中心:提供售电、售水财务报表、用能报表、报警报表等查询,本系统所有的报表及记录查询,都支持excel格式导出。

This system includes five modules, namely login module, system configuration module, user (shop) management module, electricity sales management module, and report center module. The main functions are as follows:

1) Login management: manage operator accounts and authority assignments, view system logs and other functions;

2) System configuration: configure the building, communication management machine, instrument and default parameters;

3) User management: perform operations such as account opening, account cancellation, remote opening and closing, batch operation and record query for shop users;

4) Electricity sales management: remotely sell electricity, return electricity, reconcile and record inquiries on the accounts that have been opened;

5) Report Center: Provides inquiries about electricity sales, water sales financial statements, energy use statements, alarm statements,and other report forms. All statements and record inquiries in this system support export in excel format.

用户管理 User Management

用户管理主要完成对商户的开户,销户、电表/水表批量操作、开户/销户记录查询等。

User management mainly completes the account opening of merchants, account cancellation, batch operation of electric meters/water meters, account opening/account cancellation records query, and others.

上海康桥先进制造技术创业园,上海康桥先进制造招商

用户开户 User Account Opening

系统对商铺进行开户,不仅支持 ,安科瑞 崔远航,一户一表,也支持一户多表的需要,满足项目改造后新老表切换时,老表金额转入的问题;支持峰谷电价,支持一表一电价;可对单表设置功率过载的阈值,也支持设置单表金额报警的两级阈值。

This system not only supports one household with one meter, but also supports the need for multiple meters for one household, and meets the problem of transferring the amount of the old meter when the new meter is switched after the project is renovated;It supports peak and valley electricity prices, and supports one meter for one meter. The power overload threshold can be set for the single meter, and the two-level threshold for the single meter amount alarm can also be set.

上海康桥先进制造技术创业园,上海康桥先进制造招商

系统的批量操作功能 ,针对开户状态、报警1、报警2、欠费、失联等状况分别用不同的颜色显示;远程对仪表进行 遥控 的命令类型 ,安科瑞 崔远航,型包括:电价下发、设置下发(下发报警金额阈值和过载功率阈值)、保电(强制仪表合闸)、恢复预付费(欠费自动跳闸的模式)、拉闸(强制断电)和抄表导出(导出当前所有表状态为EXCEL文件),如下图所示:

The batch operation function of the system is displayed in different colors for the status of account opening, alarm 1, alarm 2, arrears, loss of connection, and others; the types of commands for remotely controlling the meter include: electricity price issuance, setting issuance (issued) Alarm amount threshold and overload power threshold), power protection (mandatory meter closing), recovery prepayment (automatic trip mode of arrears), opening (mandatory power off) and meter reading export (export all current meter states to EXCEL files ),as shown below:

上海康桥先进制造技术创业园,上海康桥先进制造招商

能耗及报表查询 Energy consumption and report query

系统进行远程集中抄表后,还提供了辅助的能耗查询报表,为能耗分析、用能比对和安全用电提供强有力的依据。该功能用于替代不了 ,安科瑞 崔远航,分能耗分析和管理系统的功能,如果需要更加专业的能耗分析和管理,推荐另外配置安科瑞能耗管理系统Acrel-5000。

除此以外,系统还提供了多种服务 ,安科瑞 崔远航,报表以供查询,包括日/月/年财务销售统计报表、失联表/通讯管理机查询报表、实时报警/历史报警查询报表等,并支持导出打印。如下图所示:

After the system performs remote centralized meter reading, it also provides auxiliary energy consumption query reports, which provide a strong basis for energy consumption analysis, energy use comparison, and safe electricity use. This function is used to replace part of the energy consumption analysis and management system. If you need more professional energy analysis and management, it is recommended to additionally configure the Acrel-5000 energy management system.

In addition, this system also provides a variety of reports for inquiries, including daily/monthly/yearly financial sales statistics reports, missing connection tables/communication management machine query reports, real-time alarm/historical alarm query reports, etc., and supports export and printing. As shown below:

售后管理 Electricity Sales Management

系统提供了新增售电、充电、退电,明细及分类查询。

This system provides new electricity sales, charging, and withdrawal, details and classification queries.

上海康桥先进制造技术创业园,上海康桥先进制造招商

报表中心 Report Center

系统提供售电、电能销售、电能服务 ,安科瑞 崔远航,统计、管控电表、实时报警、历史事件、电参量等各种报表以供查询,满足用户找*日我**/月/年财务销售电量、收费等,以及失联表/通讯管理机查询报表。

This system provides various reports such as electricity sales, electricity sales, electricity statistics, management and control meters, real-time alarms, historical events, electrical parameters,and others for query, so as to satisfy users to find daily/month/year financial sales electricity, charges, as well as loss of connection meter /communication management machine query report.

上海康桥先进制造技术创业园,上海康桥先进制造招商

上海康桥先进制造技术创业园,上海康桥先进制造招商

系统配置 System Configuration

系统配置 ,安科瑞 崔远航,包括建筑、网关、电表、水表的平台接入基础参数设置,并提供管理人员角色和权限的管理,防止未授权的访问。

The system configuration includes platform access basic parameter settings for buildings, gateways, electricity meters, and water meters, and provides management of the roles and permissions of managers to prevent unauthorized access.

上海康桥先进制造技术创业园,上海康桥先进制造招商

单据打印 Document printing

售电、退电、开户时系统 ,安科瑞 崔远航,支持三联单单据打印的功能,单据格式默认如下(可以由客户确认后自由定制):

When selling electricity, returning electricity, and opening an account, the system supports the function of printing three-part documents. The default document format is as follows (it can be freely customized after confirmation by the customer):

上海康桥先进制造技术创业园,上海康桥先进制造招商

在线手机查询和自助购电 Online mobile phone query and self-service power purchase

上海康桥先进制造技术创业园,上海康桥先进制造招商

上海康桥先进制造技术创业园,上海康桥先进制造招商

上海康桥先进制造技术创业园,上海康桥先进制造招商

上海康桥先进制造技术创业园,上海康桥先进制造招商

4﹑结束语 Conclusions

伴随着经济的发展,人们物质生活水平的提高,为了满足人们日常购物和饮食的生活需求,各地地方涌现出一大批的商业综合体,商业 ,安科瑞 崔远航,综合体内的各个商铺和租户的用电管理亟待解决,在商业综合体的用电量不断增长、对供电质量要求不断提高的同时,也存在大量拖欠电费的情况,很大的加重了商业综合体经营管理方的经营风险。 预付费能源管理系统通过总线通讯的方式,结合现场的多用,安科瑞 崔远航,户计量表(ADF400L)和平台软件系统(Acrel-3200)实现了先交费后用电,可以避免商场电费垫资问题,从而缓解了商业地产运营的资金压力,有效的加强和改善了经营管理方式。

With the development of the economy and the improvement of people's material living standards, in order to meet people's daily shopping and eating needs, a large number of commercial complexes have emerged in various places. The electricity management of various shops and tenants in the commercial complex needs to be solved urgently. While the electricity consumption of commercial complexes continues to increase and the requirements for power supply quality continue to increase, there are also a large number of arrears in electricity bills, which greatly increases the operational risks of the commercial complex management party. The prepaid energy management system uses bus communication, combined with the on-site multi-user meter (ADF400L) and the platform software system (Acrel-3200) to realize the payment before the electricity is used, which can avoid the problem of the shopping mall’s electricity bill advancement, thereby alleviating the financial pressure of commercial real estate operations has effectively strengthened and improved the operation and management methods.

参照标准:Reference standard:

ISO/IEC11801 《国际综合布线标准》

GB/50198 《监控系统工程技术规范》

GB50052-2009 《供配电系统设计规范》

GB50054-2011 《低压配电设计规范》

IEC 61587 《电子设备机械结构系列》

DL/T448-2000 《电能计量装置技术管理规程》

DL/T 698.1-2009 《第1部分:总则》

DL/T 698.2-2010 《第2部分:主站技术规范》

DL/T 698.31-2010 《第3.1部分:电能信息采集终端技术规范-通用要求》

DL/T/814-2002 《配电自动化系统功能规范》

DL/T5137-2001 《电能测量及电能计量装置设计技术规程》

GB2887 《计算站场地技术条件》

GB/T18460.3 《IC卡预付费售电系统 第3部分: 预付费电度表》

ISO/IEC11801 "International Integrated Wiring Standard"

GB/50198 "Technical Specification for Monitoring System Engineering"

GB50052-2009 "Code for Design of Power Supply and Distribution System"

GB50054-2011 "Code for Design of Low-Voltage Power Distribution"

IEC 61587 "Electronic Equipment Mechanical Structure Series"

DL/T448-2000 "Technical Management Regulations for Electric Energy Metering Devices"

DL/T 698.1-2009 "Part 1: General Provisions"

DL/T 698.2-2010 "Part 2: Technical Specifications of the Master Station"

DL/T 698.31-2010 "Part 3.1: Technical Specifications for Electric Energy Information Collection Terminals-General Requirements"

DL/T/814-2002 "Function Specification for Distribution Automation System"

DL/T5137-2001 "Technical Regulations for the Design of Electricity Measurement and Electric Energy Metering Devices"

GB2887 "Technical Conditions of Computing Station Site"

GB/T18460.3 "IC Card Prepaid Electricity Sales System Part 3: Prepaid Electricity Meter"